‘Ductability’... |



|
Span Chart... |
|
©2008 Nucor Corporation - Vulcraft/Verco Group |
|
JOIST DIMENSIONS |
DUCT SHAPES & ALLOWABLE SIZES |
|||
|
DEPTH |
PANEL DISTANCE |
ROUND (DIAMETER) |
SQUARE |
RECTANGULAR |
|
10" |
19" |
6" |
5" |
6"x3" |
|
12" |
19" |
7" |
6" |
7"x4" |
|
14" |
19" |
8" |
6" |
9"x5" |
|
16" |
24" |
9" |
7" |
13"x5" |
|
18" |
24" |
10" |
8" |
13"x6" |
|
20" |
24" |
11" |
9" |
13"x6" |
|
|
RESIDENTIAL |
COMMERCIAL |
|
|
Total load = 117 psf |
Total load = 157 psf |
|
|
Live Load = 40 psf |
Live Load = 80 psf |
|
|
NC Dead Load = 42 psf |
NC Dead Load = 42 psf |
|
|
Comp Dead Load = 35 psf |
Comp Dead Load = 35 psf |
|
Depth |
Length |
Length |
|
10" |
25'-0" |
25'-0" |
|
12" |
30'-0" |
30'-0" |
|
14" |
35'-0" |
32'-8" |
|
16" |
40'-0" |
37'-4" |
|
18" |
45'-0" |
39'-0" |
|
20" |
46'-8" |
43'-4" |
|
Notes: |
|
|
|
1. Ecospan™ joists are typically spaced at 4'-0" on center. |
||
|
2. Shaded areas may require special chord or web members. |
||
|
3. Tables assume 3" nominal 3000 psi concrete slab. |
||